| Products |
|
|
 |
|
|
|
|
|
| |
|
|
|
| DGA-X |
|
|
DGA-X is a continues emission monitoring system designed to quantify and analyze environmental gases like SO2 and NO being emitted from industrial stacks. Using a UV light source DGA-X efficiently detect emission within UV domain. It utilizes an In-Situ type probe placed inside a stack to measure the density of gas passing it, which requires no sampling.
DGA-X is composed with a probe and a controller unit. The probe can be broken down into a number segments and they are a gas passage, windows, a mirror fixture, an optical sensor, an optical fiber assembly, and an air-purge. The controller unit also can be broken down into a number of modules and they are a light source, an optical sensor, a Monochromator, a signal processes unit, an output unit, and a power supply unit. DGA-X probe can be customized for Power Plants, Waste Treatment Plants, Steel Industry, Cement Industry, Pulp Industry, and Petrochemical Industry. |
| Benefits |
- In-situ measuring system Instantaneous monitor from aa direct gas duct. No need for gas extraction and preparation.
- One device supports both SOx and NOx reduces maintenance costs.
- DOAS approach maintains high level of accuracy filtering out dusts, humidity, and other undesired gas components.
- No need of external transceiver/receiver unit or computer system for monitoring. |
| Specification |
- Lamp: a deuterium lamp having UV spectral range between 200~250 nm is used in the light source unit. Benefits are long service life, high stability, and Intensified signal output.
- Probe: probe is made from SOx, NOx, and oxidization proof SUS316Ti material |
A. Max measurement gas temperature: 200 °C (customized on request)
B. Wet gas streams: Suitable
C. System response time: Yes
D. Purge-air supply required: 60 hPa (dep. on purge-air)
E. Max duct overpressure: ≥ 1,500mm (customized on request))
F. Minimum duct diameter: Temperature sensor
G. Integrated sensors: 1.6 / 2.1M
H. Available probe lengths: 500 / 800 mm (customized on request)
I. Weight: 15 / 20kg |
|
- Main unit: DGM-200 uses DOAS (Differential Optical Absorption Spectroscopy) approach |
A. Measuring Gas: SOx , NOx
B. Measuring Range: 0 ~ 200, 1000ppm
C. Zero Drift: < 1% /2hr , 2% /24hr
D. Span Drift: < 2% /24hr
E. Repeatability: < 2%
F. Linearity: < 5%
G. Response time: > 20s
H. Warm-up time: 5 min
I. Ambient temperature: ?20 to +50°C
J. Ambient humidity: Max 96% RH
K. Class of protection: IP 65
L. Power supply: 115/230 V AC, 50/60 Hz, 250 VA max
M. Dimensions (WxHxD): 291x530x570mm
N. Weight: 29 kg |
|
- Application Software |
A. Windows XP Base
B. Gas Spectrum Measurement
C. Control the Signal Processing Time
D. Worksheet format Data Exportation
E. Concentration Recording
F. Lamp Status Monitoring
G. User Friendly Interface
H. Flexibility for System Line-up |
|
- Data Processing Unit |
A. CPU Intel® 1.0GHz Processor
B. System Memory 1GB
C. I/O Interface RS-232/422/485, USB 2.0
D. Display Interface VGA
E. SSD CF Type II
F. Analog Output 2Ch (0, 4~20mA)
G. Digital In 7Ch
H. Digital Out 8Ch
I. Analog In 1Ch |
|
|
|
|
 |
|
|
|
|
 |
|